欧美亚洲日韩在线娱乐论坛,欧美亚洲国产一区二区三区,欧美日韩在线一区二区三区,欧美日韩一区二区三区人妻

世聯(lián)博研(北京)科技有限公司 主營:Flexcell細(xì)胞力學(xué)和regenhu細(xì)胞3D生物打印機(jī)銷售技術(shù)服務(wù): 美國Flexcell品牌FX-5000T細(xì)胞牽張應(yīng)力加載培養(yǎng)系統(tǒng),F(xiàn)X-5K細(xì)胞顯微牽張應(yīng)力加載培養(yǎng)系統(tǒng),Tissue Train三維細(xì)胞組織培養(yǎng)與測試系統(tǒng),F(xiàn)X-5000C三維細(xì)胞組織壓應(yīng)力加載培養(yǎng)系統(tǒng),STR-4000細(xì)胞流體剪切應(yīng)力加載培養(yǎng)系統(tǒng),德國cellastix品牌Optical Stretcher高通量單細(xì)胞牽引應(yīng)變與分析系統(tǒng) Regenhu品牌3D discovery細(xì)胞友好型3D生物打印機(jī),piuma細(xì)胞納米壓痕測試分析、aresis多點(diǎn)力學(xué)測試光鑷,MagneTherm細(xì)胞腫瘤電磁熱療測試分析系統(tǒng)
服務(wù)電話: 010-67529703
主營產(chǎn)品: Flexcell細(xì)胞力學(xué)和regenhu細(xì)胞3D生物打印機(jī)銷售技術(shù)服務(wù): 美國Flexcell品牌FX-5000T細(xì)胞牽張應(yīng)力加載培養(yǎng)系統(tǒng),F(xiàn)X-5K細(xì)胞顯微牽張應(yīng)力加載培養(yǎng)系統(tǒng),Tissue Train三維細(xì)胞組織培養(yǎng)與測試系統(tǒng),F(xiàn)X-5000C三維細(xì)胞組織壓應(yīng)力加載培養(yǎng)系統(tǒng),STR-4000細(xì)胞流體剪切應(yīng)力加載培養(yǎng)系統(tǒng),德國cellastix品牌Optical Stretcher高通量單細(xì)胞牽引應(yīng)變與分析系統(tǒng) Regenhu品牌3D discovery細(xì)胞友好型3D生物打印機(jī),piuma細(xì)胞納米壓痕測試分析、aresis多點(diǎn)力學(xué)測試光鑷,MagneTherm細(xì)胞腫瘤電磁熱療測試分析系統(tǒng)
聯(lián)系我們

1300A,1305A Whole Rat Muscle Test System,1310A Large Rodent Muscle Test System

  • 如果您對該產(chǎn)品感興趣的話,可以
  • 產(chǎn)品名稱:1300A,1305A Whole Rat Muscle Test System,1310A Large Rodent Muscle Test System
  • 產(chǎn)品型號:
  • 產(chǎn)品展商:aurorascientific
  • 產(chǎn)品文檔:無相關(guān)文檔
簡單介紹

加拿大Aurora公司在1997年時(shí)為從事肌肉力學(xué)研究的科學(xué)家提供力傳感器和電機(jī)。之后因?yàn)榈玫皆摽蒲蓄I(lǐng)域人士的認(rèn)可,逐漸擴(kuò)大了客戶群,所以陸續(xù)發(fā)展出刺激器,軟件和實(shí)驗(yàn)裝置等等,組合成不同的系統(tǒng),應(yīng)用于不用的實(shí)驗(yàn)之中。我們的產(chǎn)品可以是獨(dú)立銷售或是整個(gè)系列的包裝發(fā)售,務(wù)求達(dá)到盡可能完善的客制化

產(chǎn)品描述
aurorascientific品牌肌肉肌纖維機(jī)械、電刺激測試分析系統(tǒng)
型號:1200A,1250A,1300A,1350A,1400A,1500A,1600A
價(jià)格:請致電
品牌:aurorascientific

加拿大Aurora公司在1997年時(shí)為從事肌肉力學(xué)研究的科學(xué)家提供力傳感器和電機(jī)。之后因?yàn)榈玫皆摽蒲蓄I(lǐng)域人士的認(rèn)可,逐漸擴(kuò)大了客戶群,所以陸續(xù)發(fā)展出刺激器,軟件和實(shí)驗(yàn)裝置等等,組合成不同的系統(tǒng),應(yīng)用于不用的實(shí)驗(yàn)之中。我們的產(chǎn)品可以是獨(dú)立銷售或是整個(gè)系列的包裝發(fā)售,務(wù)求達(dá)到盡可能完善的客制化。

在產(chǎn)品測試的樣本或標(biāo)的物方面,從微觀到宏觀,可以是一個(gè)去膜肌肉細(xì)胞,一條肌纖維,一條肌肉,甚至是一整組肌肉所產(chǎn)生的力量。樣本可以是小鼠,大鼠,狗,羊或是豬等等。


加拿大Aurora總授權(quán)代理
世聯(lián)博研北京科技有限公司是加拿大Aurora力學(xué)設(shè)備與耗材在中國大陸區(qū)域總授權(quán)代理商, 為廣大科研用戶提供flexcell全系列產(chǎn)品,詳情致電國內(nèi)免費(fèi)客服電話:400-650-8506咨詢索取資料


一、1200A小鼠離體肌肉機(jī)械力特性測試系統(tǒng)

型號:1200A
價(jià)格:請致電
品牌:美國aurora
離體完整無缺肌肉機(jī)械特性測試系統(tǒng),離體無損肌肉機(jī)械力測試系統(tǒng)
型號:1200A - in vitro System - Mouse
價(jià)格:請致電
品牌:加拿大aurora

1200A系列大小鼠離體肌肉測試系統(tǒng)

1200A in vitro Muscle Test System



特點(diǎn):

1. 應(yīng)用于大鼠(1205A系統(tǒng))和小鼠(1200A系統(tǒng))

2. 這是一個(gè)完整的測試系統(tǒng), 可以測量單條完整無缺肌肉的機(jī)械特性, 力度峰值達(dá)至10N

3.具有不同的測試方案, 如等距抽搐, 強(qiáng)直收縮, 疲勞, 損傷, 長度-張力, 力-收縮速率, 力-刺激頻率, 硬度, 功循環(huán)等等  

4. 這個(gè)系統(tǒng)可以應(yīng)用在動(dòng)物四肢的肌肉上, 如趾長伸肌﹑ 脛骨前肌﹑ 比目魚肌﹑ 腓腸肌隔膜肌﹑細(xì) 小肌肉(如FDB 和蚓狀肌), 甚至是一些人造肌肉, 聚合物或者是薄膜。

概述:

1200A離體無損肌肉測試系統(tǒng)是一個(gè)旗艦系統(tǒng),可以測試肌肉的收縮力度和不同的機(jī)械特性。從*簡單的等距抽搐方案去到比較繁復(fù)的力量-收縮速率方案, 都能使用這個(gè)簡易的系統(tǒng)去準(zhǔn)確地測試出肌肉的各種機(jī)械參量(收縮力度, 長度變化, 收縮速率等等)。

測試過程只需要連接著肌肉其中一端的肌腱, 就可以測試和控制其力度與長度, 這大大地減少了操作時(shí)間, 同時(shí)也提高了實(shí)驗(yàn)的效能和產(chǎn)出量。

在制備過程中, 單條肌肉會(huì)直立地固定于一個(gè)供應(yīng)氧氣和營養(yǎng)液的容器之中, 在肌肉兩側(cè)會(huì)有兩條電*提供刺激。位置調(diào)節(jié)器可以令各個(gè)部件置于*佳的位置上,從放置肌肉到索取實(shí)驗(yàn)數(shù)據(jù), 讓整個(gè)實(shí)驗(yàn)流水線般的完成。

通過動(dòng)態(tài)肌肉控制和分析軟件(DMC/DMA), 能從實(shí)驗(yàn)方案設(shè)定去到數(shù)據(jù)收集和分析,大大縮短整個(gè)實(shí)驗(yàn)過程的需時(shí), 甚至于數(shù)分鐘內(nèi)完成。各種參量如安靜力, 靜息長度, 刺激頻率和實(shí)際測試的方案都可以使用軟件去進(jìn)行設(shè)定, 一些標(biāo)準(zhǔn)的實(shí)驗(yàn)方案樣本會(huì)額外提供在系統(tǒng)之中。

系統(tǒng)包括﹕

1. 肌肉杠桿系統(tǒng)﹕測試和控制力度和長度 (力度峰值10N/1000grams)

2. 可控溫水套式組織浴

3. 高功率 (電流/電壓) 電場刺激

4. 桌用電腦﹕ 配置控制和分析軟件系統(tǒng)



二、1250A大鼠離體肌肉機(jī)械力特性測試系統(tǒng)

1200A大鼠離體肌肉機(jī)械力特性測試系統(tǒng)
型號:1205A系統(tǒng)
價(jià)格:請致電
品牌:加拿大aurora
離體完整無缺肌肉機(jī)械特性測試系統(tǒng),離體無損肌肉機(jī)械力測試系統(tǒng)
型號:1200A - in vitro System - Mouse
價(jià)格:請致電
品牌:加拿大aurora

1200A系列大小鼠離體肌肉測試系統(tǒng)

1200A in vitro Muscle Test System



特點(diǎn):

1. 應(yīng)用于大鼠(1205A系統(tǒng))和小鼠(1200A系統(tǒng))

2. 這是一個(gè)完整的測試系統(tǒng), 可以測量單條完整無缺肌肉的機(jī)械特性, 力度峰值達(dá)至10N

3.具有不同的測試方案, 如等距抽搐, 強(qiáng)直收縮, 疲勞, 損傷, 長度-張力, 力-收縮速率, 力-刺激頻率, 硬度, 功循環(huán)等等  

4. 這個(gè)系統(tǒng)可以應(yīng)用在動(dòng)物四肢的肌肉上, 如趾長伸肌﹑ 脛骨前肌﹑ 比目魚肌﹑ 腓腸肌隔膜肌﹑細(xì) 小肌肉(如FDB 和蚓狀肌), 甚至是一些人造肌肉, 聚合物或者是薄膜。

概述:

1200A離體無損肌肉測試系統(tǒng)是一個(gè)旗艦系統(tǒng),可以測試肌肉的收縮力度和不同的機(jī)械特性。從*簡單的等距抽搐方案去到比較繁復(fù)的力量-收縮速率方案, 都能使用這個(gè)簡易的系統(tǒng)去準(zhǔn)確地測試出肌肉的各種機(jī)械參量(收縮力度, 長度變化, 收縮速率等等)。

測試過程只需要連接著肌肉其中一端的肌腱, 就可以測試和控制其力度與長度, 這大大地減少了操作時(shí)間, 同時(shí)也提高了實(shí)驗(yàn)的效能和產(chǎn)出量。

在制備過程中, 單條肌肉會(huì)直立地固定于一個(gè)供應(yīng)氧氣和營養(yǎng)液的容器之中, 在肌肉兩側(cè)會(huì)有兩條電*提供刺激。位置調(diào)節(jié)器可以令各個(gè)部件置于*佳的位置上,從放置肌肉到索取實(shí)驗(yàn)數(shù)據(jù), 讓整個(gè)實(shí)驗(yàn)流水線般的完成。

通過動(dòng)態(tài)肌肉控制和分析軟件(DMC/DMA), 能從實(shí)驗(yàn)方案設(shè)定去到數(shù)據(jù)收集和分析,大大縮短整個(gè)實(shí)驗(yàn)過程的需時(shí), 甚至于數(shù)分鐘內(nèi)完成。各種參量如安靜力, 靜息長度, 刺激頻率和實(shí)際測試的方案都可以使用軟件去進(jìn)行設(shè)定, 一些標(biāo)準(zhǔn)的實(shí)驗(yàn)方案樣本會(huì)額外提供在系統(tǒng)之中。

系統(tǒng)包括﹕

1. 肌肉杠桿系統(tǒng)﹕測試和控制力度和長度 (力度峰值10N/1000grams)

2. 可控溫水套式組織浴

3. 高功率 (電流/電壓) 電場刺激

4. 桌用電腦﹕ 配置控制和分析軟件系統(tǒng)

、1300A 系列原位/體內(nèi)/離體肌肉測試系統(tǒng)


型號:1300A
價(jià)格:請致電
品牌:加拿大aurora

1300A 系列原位/體內(nèi)/離體肌肉測試系統(tǒng)

1300A Intact Muscle/Whole Mouse Test System

拉長收縮,疲勞,硬度,力度-收縮速率和功循環(huán)測試系統(tǒng)

特點(diǎn):

1. 高效的三合一系統(tǒng)設(shè)計(jì):

1.1) 原位實(shí)驗(yàn)

1.2) 活體動(dòng)物體內(nèi)實(shí)驗(yàn)(踏板設(shè)計(jì))

1.3) 離體實(shí)驗(yàn)(浴盆)

2.適用于損傷和縱長等課題的活體動(dòng)物實(shí)驗(yàn)

3.可選擇25ml 浴盤應(yīng)用于離體肌肉實(shí)驗(yàn)

4.操作簡單的高產(chǎn)量測試系統(tǒng), 適用于任何經(jīng)驗(yàn)水平的研究者

概述:

1300A 三合一測試系統(tǒng)的設(shè)計(jì)主要是讓肌肉生理學(xué)家能夠通過簡易的操作去測試出大鼠或小鼠等肌肉組織的機(jī)械特性和功能參數(shù)。

1300A擁有一個(gè)獨(dú)特的雙模肌肉杠桿系統(tǒng), 通過連接著肌肉其中一端肌腱的基礎(chǔ)上, 同時(shí)進(jìn)行肌肉在收縮力度和長度變化兩方面的測量和控制,這大大地節(jié)省了實(shí)驗(yàn)需時(shí)和提高了實(shí)驗(yàn)的效能。

1300A測試系統(tǒng)可應(yīng)用于拉長收縮,疲勞,硬度,力度-收縮速率和功循環(huán)等實(shí)驗(yàn)方案, 同時(shí)具有高彈性尺度, 可以應(yīng)用於等距測試方案, 例如抽搐, 強(qiáng)直收縮和力量-刺激頻率等實(shí)驗(yàn)方案。

三個(gè)不同的實(shí)驗(yàn)裝置(體內(nèi)/離體/原位)可以輕易地在該系統(tǒng)之中進(jìn)行轉(zhuǎn)換, 例如從體內(nèi)實(shí)驗(yàn)裝置(踏板設(shè)計(jì))轉(zhuǎn)換至離體實(shí)驗(yàn)裝置(25ml浴盆),過程只需要數(shù)分鐘的時(shí)間。

系統(tǒng)包括:

1.肌肉杠桿系統(tǒng):測試和控制力度和長度 (*大力度值10N/1000grams)

2.可控溫的精密動(dòng)物平臺(tái)

3 .雙模 (電流和電壓) 神經(jīng)刺激器

4.桌用電腦﹕ 配置控制和分析軟件系統(tǒng)

5.可附加 25ml 離體實(shí)驗(yàn)浴盆

四、1500A系列細(xì)小肌肉組織機(jī)械力特性測試系統(tǒng)



型號:1500A
價(jià)格:請致電
品牌:加拿大aurora

1500A Small Intact Muscle Test System

特點(diǎn):

1.設(shè)計(jì)應(yīng)用于肌纖維, 肌肉束,單條肌肉或細(xì)小的肌肉如trabeculae

2.適用于長度-張力, 力-收縮速率和硬度等的測量

?3.力度峰值達(dá)至100mN

4.可控溫度范圍: 0-40°C

5.400μL 或1900μL循環(huán)灌流浴, 包括兩條鉑電*用以提供刺激

6.可以配合標(biāo)準(zhǔn)顯微鏡或者倒置顯微鏡

7.可選擇單一等距實(shí)驗(yàn)?zāi)J?

概述:

1500A是一個(gè)一站式系統(tǒng), 可以讓從事生理學(xué)研究方面 的科學(xué)家更簡單快捷地去測試細(xì)小組織的機(jī)械特性,例如*普遍的力度參量。

該系統(tǒng)的實(shí)驗(yàn)裝置配合于絕大部份的倒置顯微鏡, 應(yīng)用于成像觀察和螢光測量。實(shí)驗(yàn)裝置擁有兩個(gè)不同大小的浴盤供以選擇去對應(yīng)細(xì)小或是中等尺寸的樣本??煽販卦∨鑲溆腥芤貉h(huán)灌流的裝置和兩條內(nèi)置的鉑金電*以提供不同型態(tài)的電刺激。系統(tǒng)同時(shí)備有一個(gè)1L水庫為浴盆供應(yīng)含氧媒體。


1500A 可以測試控制的力度和長度, 使其應(yīng)用范圍更廣泛, 從簡單的張力測試去到樣本組織完整的機(jī)械特性(例如長度-張力,力-收縮速率和硬度)都能夠被測試。附加的軟件程序(600A) 備有各種標(biāo)的實(shí)驗(yàn)方案去配合不同的實(shí)驗(yàn)需求。

力傳感器通過浴盆其中一端的小槽與樣本組織連接著, 該設(shè)計(jì)令浴盆的底部可以被有機(jī)玻璃密封, 從而非常適用于進(jìn)行人工心肌組織或一些高氧耗量的研究。因?yàn)榕渲孟拗菩院艿停?1500A 是一個(gè)非常理想的測試系統(tǒng)去應(yīng)用于細(xì)小肌肉組織方面的實(shí)驗(yàn)。

完整的系統(tǒng)包括:

● 高速長度操控儀

●  400A力傳感器

● 高配置度的實(shí)驗(yàn)浴盆

● 電場刺激器

●桌用電腦﹕ 配置控制和分析軟件系統(tǒng)

● 溫度控制器和冷卻液循環(huán)器

● 1升灌流水庫

● 可附加肌小節(jié)間隔長度檢測軟件(HVSL/ VSL)

六、1600A透性肌肉(去膜)細(xì)胞測試系統(tǒng)



1600A透性肌肉(去膜)細(xì)胞測試系統(tǒng)
型號:1600A
價(jià)格:請致電
品牌:美國aurora

 

1600A 透性肌肉細(xì)胞測試系統(tǒng)

803B Permeabilized Myocyte Test System


特點(diǎn):

?  應(yīng)用于透性 (去膜) 心肌細(xì)胞的研究

?  測試kTR, 力-鈣離子濃度, 長度-張力, 力-收縮速率和硬度等機(jī)械特性

?  備有8個(gè)溶液小槽的寛闊平臺(tái)以盛載不同濃度的鈣離子溶液

?  電動(dòng)化三維微定位裝置以準(zhǔn)確和快速地將樣本定位

?  可以配合標(biāo)準(zhǔn)顯微鏡或者倒置顯微鏡

?  可控溫度范圍: 0-40°C

1600A 是一個(gè)可靠和可重復(fù)性的實(shí)驗(yàn)測試系統(tǒng),應(yīng)用于測試去膜心肌細(xì)胞的主動(dòng)和被動(dòng)性質(zhì)。透過使用其搖桿控制電動(dòng)化定位裝置可以輕易地令細(xì)胞的兩端分別連接于力傳感器和高速伺服電機(jī),這大大提高了實(shí)驗(yàn)效能和簡化了原本精細(xì)的樣本連接程序。

可控溫浴盆擁有8個(gè)溶液小槽令細(xì)胞可以輕易地在不同濃度的鈣離子溶液之間進(jìn)行轉(zhuǎn)換,該裝置會(huì)直接放置在倒置顯微鏡的置物平臺(tái)上進(jìn)行高清晰度的觀察和肌節(jié)間距的檢測。可選擇附加一塊棱鏡去準(zhǔn)確地檢測出細(xì)胞于溶液槽的深度。

1400A測試系統(tǒng)可以控制和測試力度, 長度和肌小節(jié)的間隔長度(當(dāng)使用可附加的高速視頻肌節(jié)長度系統(tǒng)) ,使其應(yīng)用范圍更廣泛, 從簡單的力-鈣離子濃度曲線去到樣本完整的機(jī)械特性(例如kTR, 長度-張力, 力-收縮速率和硬度) 都能夠被測試。附加的軟件程序(600A) 備有各種標(biāo)準(zhǔn)的實(shí)驗(yàn)方案去配合不同的實(shí)驗(yàn)需求。

完整系統(tǒng)包括:

●高速長度操控儀

● 400A力傳感器

●電動(dòng)化三維微定位平臺(tái)

●帶有8個(gè)溶液小槽的可控溫平臺(tái)

●客制桌用電腦(附加螢?zāi)?: 配有控制和分析軟件系統(tǒng)

●溫度控制器和冷卻液循環(huán)器

●可附加肌小節(jié)間隔長度檢測軟件(HVSL/ VSL)

應(yīng)用文獻(xiàn):

一、心肌細(xì)胞和肌肉文獻(xiàn)

American Journal of …, 2005 - Am Physiological Soc
... Power output is linearly related to MyHC content in rat skinned myocytes and isolated working
hearts. ... were made using a capacitance-gauge transducer (model 403; sensitivity, 20 mV/mg plus
a x10 amplifier; resonant frequency, 600 Hz; Aurora Scientific; Aurora, Ontario ...
Cited by 45 - Related articles - Get at CISTI - All 5 versions
Altered single cell force-velocity and power properties in exercise-trained rat myocardium
[HTML] from physiology.org


GM Diffee… - Journal of Applied Physiology, 2003 - Am Physiological Soc
... The resulting skinned myocytes were resuspended in 8–10 ml of relaxing solution and kept on
ice throughout the days ... described previously (8). Skinned cardiac myocyte preparations were
attached between a capacitance-gauge transducer (model 403, Aurora Scientific) and a ...
Cited by 25 - Related articles - Get at CISTI - All 8 versions
Regional differences in effects of exercise training on contractile and biochemical properties of rat cardiac
myocytes
[HTML] from physiology.org


GM Diffee… - Journal of Applied Physiology, 2003 - Am Physiological Soc
... The resulting skinned myocytes were resuspended in 8–10 ml of relaxing solution and kept on
ice throughout the days ... described previously (9). Skinned cardiac myocyte preparations were
attached between a capacitance-gauge transducer (model 403, Aurora Scientific) and a ...
Cited by 24 - Related articles - Get at CISTI - All 5 versions
Force-length relations in isolated intact cardiomyocytes subjected to dynamic changes in mechanical load
[HTML] from physiology.org


G Iribe, M Helmes… - American Journal of Physiology- …, 2007 - Am Physiological Soc
... Gentaro Iribe, 1 Michiel Helmes, 1 ,2 and Peter Kohl 1. ... CCD, charge-coupled device. K was
measured directly, using a force transducer system (406A; Aurora Scientific, Aurora, ON, Canada)
factory calibrated for compression measurement, and mounted under a microscope. ...
Cited by 30 - Related articles - Get at CISTI - All 7 versions
Mouse intact cardiac myocyte mechanics: cross-bridge and titin-based stress in unactivated cells
[HTML] from rupress.org


…, N Harrell, CS Chung, M Helmes… - The Journal of …, 2011 - jgp.rupress.org
... Results were compared with those of previous studies on skinned myocytes (Helmes et al., 1996,
2003; Preetha et al., 2005) and ... fibers protruding from pipette tip), and their stiffness was determined
by cross-calibrating with a force transducer (model 406A; Aurora Scientific). ...
Cited by 5 - Related articles - All 6 versions
Calcium sensitivity and the Frank-Starling mechanism of the heart are increased in titin N2B region-deficient mice
[HTML] from nih.gov


EJ Lee, J Peng, M Radke, M Gotthardt… - Journal of molecular and …, 2010 - Elsevier
... papillary muscles were dissected into small strips (cross-sectional area (CSA) 0.02 mm 2 ; length
1.2 mm) and small aluminum clips were glued to the ends of the muscle [33] in order to attach
the muscle at one end to a force transducer (model 406, Aurora Scientific) and at the ...
Cited by 5 - Related articles - All 6 versions
Analysing force–pCa curves
[HTML] from nih.gov

 


JS Walker, X Li… - Journal of muscle research and cell motility, 2010 - Springer
... Department of Medicine, University of Colorado Denver, Aurora, CO 80045, USA e-mail:
john.s.walker@ucdenver.edu ... contrast ability at magnifications up to 400 9 . Sarcomere length
was measured for each myocyte using a image based system (Aurora Scientific 901A HSVL ...
Cited by 4 - Related articles - All 7 versions
Mouse intact cardiac myocyte mechanics: cross-bridge and titin-based stress in unactivated cells

[HTML] from rupress.org
NMP King, M Methawasin, J Nedrud… - The Journal of …, 2011 - jgp.rupress.org
... Next, 10 ml of myocyte stopping buffer 2 was added (perfusion buffer plus 0.05 ml BCS/ml buffer
and 12.5 μM CaCl 2 ... mm of carbon fibers protruding from pipette tip), and their stiffness was
determined by cross-calibrating with a force transducer (model 406A; Aurora Scientific). ...
Cited by 5 - Related articles - All 6 versions
Inorganic phosphate speeds loaded shortening in rat skinned cardiac myocytes
[HTML] from physiology.org

 


AC Hinken… - American Journal of Physiology- …, 2004 - Am Physiological Soc
... were introduced at one end of the preparation with a direct current (DC) torque motor (model
308; Aurora Scientific) driven by ... window In a new window. Table 2. Effects of P i addition on
mechanical properties of skinned cardiac myocyte preparations. ... 2. Araujo A and Walker JW. ...
Cited by 16 - Related articles - Get at CISTI - All 5 versions
Protein Kinase A–Mediated Acceleration of the Stretch Activation Response in Murine Skinned Myocardium Is
Eliminated by Ablation of cMyBP-C
[HTML] from ahajournals.org

 


JE Stelzer, JR Patel… - Circulation research, 2006 - Am Heart Assoc
... The ends of the preparation were attached to the arms of a motor (model 312B, Aurora Scientific)
and force transducer (model 403, Aurora Scientific), as described earlier. ... Circ Res. 1998; 83:
471–480. Abstract/FREE Full Text. ? de Tombe PP, Stienen GJM. ...
Cited by 41 - Related articles - Get at CISTI - All 7 versions
Cycling cross-bridges increase myocardial stiffness at submaximal levels of Ca2+ activation
[HTML] from nih.gov

 


KS Campbell, JR Patel… - Biophysical journal, 2003 - Elsevier
... 913 ± 53 μm, width 130 ± 12 μm) were connected between a motor (Model 312B, time for
100-μm step 1 ms, Aurora Scientific, Ontario, Canada ... Many previous reports (Noble, 1977; Chiu
et al., 1982; de Tombe and ter Keurs, 1992; [Stuyvers et al., 1997] and [Stuyvers et al., 1998 ...
Cited by 26 - Related articles - Get at CISTI - All 11 versions
Effect of stimulation rate, sarcomere length and Ca2+ on force generation by mouse cardiac muscle
[HTML] from physoc.org


BD Stuyvers, AD McCulloch, J Guo… - The Journal of …, 2002 - Physiological Soc
... The length of the muscle (ML) was set using a servo-controlled motor (model 318 B, Aurora
Scientific Inc., Aurora, ON, Canada) hooked to ... carbon fibre rod, constituted the force transducer
so that the resolution of the force measurement system was 0.5 μN(yùn) (see Stuyvers et al. ...
Cited by 45 - Related articles - Get at CISTI - All 10 versions
Effects of thin and thick filament proteins on calcium binding and exchange with cardiac troponin C
[HTML] from nih.gov

 


JP Davis, C Norman, T Kobayashi, RJ Solaro… - Biophysical journal, 2007 - Elsevier
... Aluminum T-clips were used to mount the trabecula between the arms of a high-speed
length controller (model 322C, Aurora Scientific, Ontario, Canada) and an isometric force
transducer (model 403A, Aurora Scientific) in relaxing solution. ...
Cited by 39 - Related articles - Get at CISTI - All 8 versions
Fabrication and Evaluation of Reconstructed Cardiac Tissue and Its Application to Bio-actuated Microdevices
H Horiguchi, K Imagawa, T Hoshino… - NanoBioscience, …, 2009 - ieeexplore.ieee.org
... D. Contractile Force Measurement of the Reconstructed Cardiac Tissue The contractile force of
the reconstructed cardiac tissue was measured using a force transducer. One end of the tissue
was fixed to a permeabilized fiber test apparatus (803B, Aurora Page 3. ...
Cited by 3 - Related articles - All 4 versions
The mechanoelectric feedback: a novel “calcium clamp” method, using tetanic contraction, for testing the role of
the intracellular free calcium
Y Yaniv, C Levy… - … of the New York Academy of …, 2006 - Wiley Online Library
... 308B, Aurora Scientific, Richmond Hill, Ontario, Canada) with a rise time of 250 μsec. ... from the
rat right ventricle (Spargue Dawley, 250–300 g). The dissection and the technique of mounting
the trabeculae in the experiment setup followed the procedures developed by ter Keurs. ...

Cited by 2 - Related articles - BL Direct - All 7 versions
Length dependence of force generation exhibit similarities between rat cardiac myocytes and skeletal muscle
fibres
[HTML] from physoc.org

LM Hanft… - The Journal of Physiology, 2010 - Wiley Online Library
... Length changes were introduced using a DC torque motor (model 308, Aurora Scientific, Inc.)
driven by voltage commands from a ... The kinetics of force redevelopment were obtained using
a procedure previously described for skinned cardiac myocyte preparations (Korte et al. ...

二、活體動(dòng)物肌肉機(jī)械特性測試文獻(xiàn)

Plasmid-based gene transfer in mouse skeletal muscle by electroporation
JD Schertzer, GS Lynch - METHODS IN MOLECULAR BIOLOGY- …, 2008 - Springer
... 1. The measurement of TA muscle function in situ requires a suitable platform (which is usually
Plexiglas) to secure the anesthetized mouse and for appropriate positioning of the servomotor. ...
Suitable systems are commer- cially available (Aurora Scientific, Aurora, ON, Canada). ...
Cited by 7 - Related articles - BL Direct - All 4 versions

[HTML] < em> In Vivo</em> Canine Muscle Function Assay
[HTML] from jove.com


MK Childers, RW Grange… - Journal of Visualized …, 2011 - jove.com
... Stimulator, Grass, S88X, Stimulus isolation unit, Grass, SIU-C, Muscle lever system, Aurora
Scientific, 310C-LR, Footplate option. Signal interface, Aurora Scientific, Series 604A, Dynamic
Muscle Control & Analysis Software, Aurora Scientific, Aurora Scientific, ...
Cited by 1 - Related articles - Cached - All 4 versions
Monitoring Murine Skeletal Muscle Function for Muscle Gene Therapy
[HTML] from nih.gov


CH Hakim, D Li, D Duan, CH Hakim, D Li… - Methods in molecular …, 2011 - Springer
... 1. Physiological saline (0.9% NaCl). 2. In situ muscle function assay system (Aurora
Scientific). The system consists of a 305C-LR dual mode transducer, a 701B stimulator,
a 604A signal interface, and an 809A footplate apparatus (Fig. 1c). ...
Androgen replacement therapy improves function in male rat muscles independently of hypertrophy and
activation of the Akt/mTOR pathway
C Hourde, C Jagerschmidt… - Acta …, 2009 - Wiley Online Library
... The right limbs were fixed with clamps (806A; Aurora Scientific, Aurora, Canada). The distal
tendons of the right soleus muscles were attached to a dual-mode lever arm system that measures
muscle isometric force (300C; Aurora Scientific) using a silk ligature. ...
Glutamine preserves skeletal muscle force during an inflammatory insult
BM Meador… - Muscle & nerve, 2009 - Wiley Online Library
... Force was measured using a dual-mode lever system, which controlled both length and
force/speed (305C-LR; Aurora Scientific). ... The ankle of the mouse was fixed in the servomotor's
footplate, with the talus (rotational center of the ankle joint) aligned with the servomotor axis. ...
Cited by 8 - Related articles - All 4 versions
Sarcolipin overexpression in rat slow twitch muscle inhibits sarcoplasmic reticulum Ca2+ uptake and impairs
contractile function
[HTML] from jbc.org

AR Tupling, M Asahi… - Journal of Biological Chemistry, 2002 - ASBMB
... Three days after DNA injection, electrically evoked muscle force was assessed in situ from the
soleus muscle from each hindlimb across a range ... using a Grass S88 stimulator, and force data
were collected on-line using a 640A signal interface (Aurora Scientific Inc.) connected ...
Cited by 45 - Related articles - BL Direct - All 4 versions
Tibialis anterior muscles in mdx mice are highly susceptible to contraction-induced injury
[PDF] from 141.213.232.243
C Dellorusso, RW Crawford, JS Chamberlain… - Journal of muscle …, 2001 - Springer
... no. 85-23 (NIH), Revised 1985, Office of Science and Health reports, Bethesda, MD). In
situ preparation ... The tendon of the muscle was tied securely to the lever arm of a servomotor
(Model 305B-LR, Aurora Scientific, Richmond Hill, ON, Canada). ...

產(chǎn)品留言
標(biāo)題
聯(lián)系人
聯(lián)系電話
內(nèi)容
驗(yàn)證碼
點(diǎn)擊換一張
注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發(fā)送信息!
2.如有必要,請您留下您的詳細(xì)聯(lián)系方式!
Copyright@ 2003-2025  世聯(lián)博研(北京)科技有限公司版權(quán)所有      電話:13466675923 傳真: 地址:北京市海淀區(qū)西三旗上奧世紀(jì)中心A座9層906 郵編:100096

白城市| 金塔县| 林甸县| 呈贡县| 武威市| 榆中县| 河源市| 遵义县| 黎川县| 安康市| 扎鲁特旗| 廉江市| 金塔县| 襄垣县| 邹城市| 元氏县| 湘乡市| 策勒县| 灌南县| 蕲春县| 长子县| 龙岩市| 龙州县| 武威市| 黔西县| 台北市| 彩票| 辽中县| 洞头县| 铜鼓县| 绍兴县| 左云县| 南和县| 井陉县| 峨边| 无极县| 宜君县| 潼关县| 韶关市| 隆安县| 汝州市|