欧美亚洲日韩在线娱乐论坛,欧美亚洲国产一区二区三区,欧美日韩在线一区二区三区,欧美日韩一区二区三区人妻

世聯(lián)博研(北京)科技有限公司 主營:Flexcell細胞力學和regenhu細胞3D生物打印機銷售技術服務: 美國Flexcell品牌FX-5000T細胞牽張應力加載培養(yǎng)系統(tǒng),F(xiàn)X-5K細胞顯微牽張應力加載培養(yǎng)系統(tǒng),Tissue Train三維細胞組織培養(yǎng)與測試系統(tǒng),F(xiàn)X-5000C三維細胞組織壓應力加載培養(yǎng)系統(tǒng),STR-4000細胞流體剪切應力加載培養(yǎng)系統(tǒng),德國cellastix品牌Optical Stretcher高通量單細胞牽引應變與分析系統(tǒng) Regenhu品牌3D discovery細胞友好型3D生物打印機,piuma細胞納米壓痕測試分析、aresis多點力學測試光鑷,MagneTherm細胞腫瘤電磁熱療測試分析系統(tǒng)
服務電話: 010-67529703
主營產品: Flexcell細胞力學和regenhu細胞3D生物打印機銷售技術服務: 美國Flexcell品牌FX-5000T細胞牽張應力加載培養(yǎng)系統(tǒng),F(xiàn)X-5K細胞顯微牽張應力加載培養(yǎng)系統(tǒng),Tissue Train三維細胞組織培養(yǎng)與測試系統(tǒng),F(xiàn)X-5000C三維細胞組織壓應力加載培養(yǎng)系統(tǒng),STR-4000細胞流體剪切應力加載培養(yǎng)系統(tǒng),德國cellastix品牌Optical Stretcher高通量單細胞牽引應變與分析系統(tǒng) Regenhu品牌3D discovery細胞友好型3D生物打印機,piuma細胞納米壓痕測試分析、aresis多點力學測試光鑷,MagneTherm細胞腫瘤電磁熱療測試分析系統(tǒng)
聯(lián)系我們

單細胞肌力測定系統(tǒng)

  • 如果您對該產品感興趣的話,可以
  • 產品名稱:單細胞肌力測定系統(tǒng)
  • 產品型號:SENZA
  • 產品展商:aurorascientific
  • 產品文檔:無相關文檔
簡單介紹

加拿大aurorascientific公司在1997年時為從事肌肉力學研究的科學家提供力傳感器和電機。之后因為得到該科研領域人士的認可,逐漸擴大了客戶群,所以陸續(xù)發(fā)展出刺激器,軟件和實驗裝置等等,組合成不同的系統(tǒng),應用于不用的實驗之中。我們的產品可以是獨立銷售或是整個系列的包裝發(fā)售,務求達到盡可能完善的客制化。 在產品測試的樣本或標的物方面,從微觀到宏觀,可以是一個去膜肌肉細胞,一條肌纖維,一條肌肉,甚至是一整組肌肉所產生的力量。樣本可以是小鼠,大鼠,狗,羊或是豬等等。

產品描述

加拿大Aurora公司在1997年時為從事肌肉力學研究的科學家提供力傳感器和電機。之后因為得到該科研領域人士的認可,逐漸擴大了客戶群,所以陸續(xù)發(fā)展出刺激器,軟件和實驗裝置等等,組合成不同的系統(tǒng),應用于不用的實驗之中。我們的產品可以是獨立銷售或是整個系列的包裝發(fā)售,務求達到盡可能完善的客制化。

在產品測試的樣本或標的物方面,從微觀到宏觀,可以是一個去膜肌肉細胞,一條肌纖維,一條肌肉,甚至是一整組肌肉所產生的力量。樣本可以是小鼠,大鼠,狗,羊或是豬等等。


加拿大Aurora總授權代理
世聯(lián)博研北京科技有限公司是加拿大Aurora力學設備與耗材在中國大陸區(qū)域總授權代理商, 為廣大科研用戶提供flexcell全系列產品,詳情致電國內免費客服電話:400-650-8506咨詢索取資料


一、1200A小鼠離體肌肉機械力特性測試系統(tǒng)

型號:1200A
價格:請致電:010-67529703
品牌:美國aurora
離體完整無缺肌肉機械特性測試系統(tǒng),離體無損肌肉機械力測試系統(tǒng)
型號:1200A - in vitro System - Mouse
價格:請致電:010-67529703
品牌:美國aurora

1200A系列大小鼠離體肌肉測試系統(tǒng)

1200A in vitro Muscle Test System



特點:

1. 應用于大鼠(1205A系統(tǒng))和小鼠(1200A系統(tǒng))

2. 這是一個完整的測試系統(tǒng), 可以測量單條完整無缺肌肉的機械特性, 力度峰值達至10N

3.具有不同的測試方案, 如等距抽搐, 強直收縮, 疲勞, 損傷, 長度-張力, 力-收縮速率, 力-刺激頻率, 硬度, 功循環(huán)等等  

4. 這個系統(tǒng)可以應用在動物四肢的肌肉上, 如趾長伸肌﹑ 脛骨前肌﹑ 比目魚肌﹑ 腓腸肌隔膜肌﹑細 小肌肉(如FDB 和蚓狀肌), 甚至是一些人造肌肉, 聚合物或者是薄膜。

概述:

1200A離體無損肌肉測試系統(tǒng)是一個旗艦系統(tǒng),可以測試肌肉的收縮力度和不同的機械特性。從*簡單的等距抽搐方案去到比較繁復的力量-收縮速率方案, 都能使用這個簡易的系統(tǒng)去準確地測試出肌肉的各種機械參量(收縮力度, 長度變化, 收縮速率等等)。

測試過程只需要連接著肌肉其中一端的肌腱, 就可以測試和控制其力度與長度, 這大大地減少了操作時間, 同時也提高了實驗的效能和產出量。

在制備過程中, 單條肌肉會直立地固定于一個供應氧氣和營養(yǎng)液的容器之中, 在肌肉兩側會有兩條電*提供刺激。位置調節(jié)器可以令各個部件置于*佳的位置上,從放置肌肉到索取實驗數(shù)據(jù), 讓整個實驗流水線般的完成。

通過動態(tài)肌肉控制和分析軟件(DMC/DMA), 能從實驗方案設定去到數(shù)據(jù)收集和分析,大大縮短整個實驗過程的需時, 甚至于數(shù)分鐘內完成。各種參量如安靜力, 靜息長度, 刺激頻率和實際測試的方案都可以使用軟件去進行設定, 一些標準的實驗方案樣本會額外提供在系統(tǒng)之中。

系統(tǒng)包括﹕

1. 肌肉杠桿系統(tǒng)﹕測試和控制力度和長度 (力度峰值10N/1000grams)

2. 可控溫水套式組織浴

3. 高功率 (電流/電壓) 電場刺激

4. 桌用電腦 (附加螢幕) ﹕ 配置控制和分析軟件系統(tǒng)



二、1250A大鼠離體肌肉機械力特性測試系統(tǒng)

1200A大鼠離體肌肉機械力特性測試系統(tǒng)
型號:1205A系統(tǒng)
價格:請致電:010-67529703
品牌:美國aurora
離體完整無缺肌肉機械特性測試系統(tǒng),離體無損肌肉機械力測試系統(tǒng)
型號:1200A - in vitro System - Mouse
價格:請致電:010-67529703
品牌:美國aurora

1200A系列大小鼠離體肌肉測試系統(tǒng)

1200A in vitro Muscle Test System



特點:

1. 應用于大鼠(1205A系統(tǒng))和小鼠(1200A系統(tǒng))

2. 這是一個完整的測試系統(tǒng), 可以測量單條完整無缺肌肉的機械特性, 力度峰值達至10N

3.具有不同的測試方案, 如等距抽搐, 強直收縮, 疲勞, 損傷, 長度-張力, 力-收縮速率, 力-刺激頻率, 硬度, 功循環(huán)等等  

4. 這個系統(tǒng)可以應用在動物四肢的肌肉上, 如趾長伸肌﹑ 脛骨前肌﹑ 比目魚肌﹑ 腓腸肌隔膜肌﹑細 小肌肉(如FDB 和蚓狀肌), 甚至是一些人造肌肉, 聚合物或者是薄膜。

概述:

1200A離體無損肌肉測試系統(tǒng)是一個旗艦系統(tǒng),可以測試肌肉的收縮力度和不同的機械特性。從*簡單的等距抽搐方案去到比較繁復的力量-收縮速率方案, 都能使用這個簡易的系統(tǒng)去準確地測試出肌肉的各種機械參量(收縮力度, 長度變化, 收縮速率等等)。

測試過程只需要連接著肌肉其中一端的肌腱, 就可以測試和控制其力度與長度, 這大大地減少了操作時間, 同時也提高了實驗的效能和產出量。

在制備過程中, 單條肌肉會直立地固定于一個供應氧氣和營養(yǎng)液的容器之中, 在肌肉兩側會有兩條電*提供刺激。位置調節(jié)器可以令各個部件置于*佳的位置上,從放置肌肉到索取實驗數(shù)據(jù), 讓整個實驗流水線般的完成。

通過動態(tài)肌肉控制和分析軟件(DMC/DMA), 能從實驗方案設定去到數(shù)據(jù)收集和分析,大大縮短整個實驗過程的需時, 甚至于數(shù)分鐘內完成。各種參量如安靜力, 靜息長度, 刺激頻率和實際測試的方案都可以使用軟件去進行設定, 一些標準的實驗方案樣本會額外提供在系統(tǒng)之中。

系統(tǒng)包括﹕

1. 肌肉杠桿系統(tǒng)﹕測試和控制力度和長度 (力度峰值10N/1000grams)

2. 可控溫水套式組織浴

3. 高功率 (電流/電壓) 電場刺激

4. 桌用電腦 (附加螢幕) ﹕ 配置控制和分析軟件系統(tǒng)

、1300A 系列原位/體內/離體肌肉測試系統(tǒng)


型號:1300A
價格:請致電:010-67529703
品牌:美國aurora

1300A 系列原位/體內/離體肌肉測試系統(tǒng)

1300A Intact Muscle/Whole Mouse Test System

拉長收縮,疲勞,硬度,力度-收縮速率和功循環(huán)測試系統(tǒng)

特點:

1. 高效的三合一系統(tǒng)設計:

1.1) 原位實驗

1.2) 活體動物體內實驗(踏板設計)

1.3) 離體實驗(浴盆)

2.適用于損傷和縱長等課題的活體動物實驗

3.可選擇25ml 浴盤應用于離體肌肉實驗

4.操作簡單的高產量測試系統(tǒng), 適用于任何經驗水平的研究者

概述:

1300A 三合一測試系統(tǒng)的設計主要是讓肌肉生理學家能夠通過簡易的操作去測試出大鼠或小鼠等肌肉組織的機械特性和功能參數(shù)。

1300A擁有一個獨特的雙模肌肉杠桿系統(tǒng), 通過連接著肌肉其中一端肌腱的基礎上, 同時進行肌肉在收縮力度和長度變化兩方面的測量和控制,這大大地節(jié)省了實驗需時和提高了實驗的效能。

1300A測試系統(tǒng)可應用于拉長收縮,疲勞,硬度,力度-收縮速率和功循環(huán)等實驗方案, 同時具有高彈性尺度, 可以應用於等距測試方案, 例如抽搐, 強直收縮和力量-刺激頻率等實驗方案。

三個不同的實驗裝置(體內/離體/原位)可以輕易地在該系統(tǒng)之中進行轉換, 例如從體內實驗裝置(踏板設計)轉換至離體實驗裝置(25ml浴盆),過程只需要數(shù)分鐘的時間。

系統(tǒng)包括:

1.肌肉杠桿系統(tǒng):測試和控制力度和長度 (*大力度值10N/1000grams)

2.可控溫的精密動物平臺

3 .雙模 (電流和電壓) 神經刺激器

4.桌用電腦 (附加螢幕) ﹕ 配置控制和分析軟件系統(tǒng)

5.可附加 25ml 離體實驗浴盆

四、1500A系列細小肌肉組織機械力特性測試系統(tǒng)



型號:1500A
價格:請致電:010-67529703
品牌:美國aurora

1500A Small Intact Muscle Test System

特點:

1.設計應用于肌纖維, 肌肉束,單條肌肉或細小的肌肉如trabeculae

2.適用于長度-張力, 力-收縮速率和硬度等的測量

?3.力度峰值達至100mN

4.可控溫度范圍: 0-40°C

5.400μL 或1900μL循環(huán)灌流浴, 包括兩條鉑電*用以提供刺激

6.可以配合標準顯微鏡或者倒置顯微鏡

7.可選擇單一等距實驗模式

概述:

 1500A是一個一站式系統(tǒng), 可以讓從事生理學研究方面 的科學家更簡單快捷地去測試細小組織的機械特性,例如*普遍的力度參量。

該系統(tǒng)的實驗裝置配合于絕大部份的倒置顯微鏡, 應用于成像觀察和螢光測量。實驗裝置擁有兩個不同大小的浴盤供以選擇去對應細小或是中等尺寸的樣本??煽販卦∨鑲溆腥芤貉h(huán)灌流的裝置和兩條內置的鉑金電*以提供不同型態(tài)的電刺激。系統(tǒng)同時備有一個1L水庫為浴盆供應含氧媒體。


1500A 可以測試控制的力度和長度, 使其應用范圍更廣泛, 從簡單的張力測試去到樣本組織完整的機械特性(例如長度-張力,力-收縮速率和硬度)都能夠被測試。附加的軟件程序(600A) 備有各種標的實驗方案去配合不同的實驗需求。

力傳感器通過浴盆其中一端的小槽與樣本組織連接著, 該設計令浴盆的底部可以被有機玻璃密封, 從而非常適用于進行人工心肌組織或一些高氧耗量的研究。因為配置限制性很低, 1500A 是一個非常理想的測試系統(tǒng)去應用于細小肌肉組織方面的實驗。

完整的系統(tǒng)包括:

● 高速長度操控儀

●  400A力傳感器

● 高配置度的實驗浴盆

● 電場刺激器

●桌用電腦 (附加螢幕) ﹕ 配置控制和分析軟件系統(tǒng)

● 溫度控制器和冷卻液循環(huán)器

● 1升灌流水庫

● 可附加肌小節(jié)間隔長度檢測軟件(HVSL/ VSL)

六、1600A透性肌肉(去膜)細胞測試系統(tǒng)


型號:1600A
價格:請致電:010-67529703
品牌:美國aurora



1600A 透性肌肉細胞測試系統(tǒng)

803B Permeabilized Myocyte Test System



特點:


?  應用于透性 (去膜) 心肌細胞的研究

?  測試kTR, 力-鈣離子濃度, 長度-張力, 力-收縮速率和硬度等機械特性

?  備有8個溶液小槽的寛闊平臺以盛載不同濃度的鈣離子溶液

?  電動化三維微定位裝置以準確和快速地將樣本定位

?  可以配合標準顯微鏡或者倒置顯微鏡

?  可控溫度范圍: 0-40°C

1600A 是一個可靠和可重復性的實驗測試系統(tǒng),應用于測試去膜心肌細胞的主動和被動性質。透過使用其搖桿控制電動化定位裝置可以輕易地令細胞的兩端分別連接于力傳感器和高速伺服電機,這大大提高了實驗效能和簡化了原本精細的樣本連接程序。

可控溫浴盆擁有8個溶液小槽令細胞可以輕易地在不同濃度的鈣離子溶液之間進行轉換,該裝置會直接放置在倒置顯微鏡的置物平臺上進行高清晰度的觀察和肌節(jié)間距的檢測??蛇x擇附加一塊棱鏡去準確地檢測出細胞于溶液槽的深度。

1400A測試系統(tǒng)可以控制和測試力度, 長度和肌小節(jié)的間隔長度(當使用可附加的高速視頻肌節(jié)長度系統(tǒng)) ,使其應用范圍更廣泛, 從簡單的力-鈣離子濃度曲線去到樣本完整的機械特性(例如kTR, 長度-張力, 力-收縮速率和硬度) 都能夠被測試。附加的軟件程序(600A) 備有各種標準的實驗方案去配合不同的實驗需求。

完整系統(tǒng)包括:

●高速長度操控儀

● 400A力傳感器

●電動化三維微定位平臺

●帶有8個溶液小槽的可控溫平臺

●客制桌用電腦(附加螢幕): 配有控制和分析軟件系統(tǒng)

●溫度控制器和冷卻液循環(huán)器

●可附加肌小節(jié)間隔長度檢測軟件(HVSL/ VSL)

應用文獻:

一、心肌細胞和肌肉文獻


American Journal of …, 2005 - Am Physiological Soc
... Power output is linearly related to MyHC content in rat skinned myocytes and isolated working
hearts. ... were made using a capacitance-gauge transducer (model 403; sensitivity, 20 mV/mg plus
a x10 amplifier; resonant frequency, 600 Hz; Aurora Scientific; Aurora, Ontario ...
Cited by 45 - Related articles - Get at CISTI - All 5 versions
Altered single cell force-velocity and power properties in exercise-trained rat myocardium
[HTML] from physiology.org




GM Diffee… - Journal of Applied Physiology, 2003 - Am Physiological Soc
... The resulting skinned myocytes were resuspended in 8–10 ml of relaxing solution and kept on
ice throughout the days ... described previously (8). Skinned cardiac myocyte preparations were
attached between a capacitance-gauge transducer (model 403, Aurora Scientific) and a ...
Cited by 25 - Related articles - Get at CISTI - All 8 versions
Regional differences in effects of exercise training on contractile and biochemical properties of rat cardiac
myocytes
[HTML] from physiology.org




GM Diffee… - Journal of Applied Physiology, 2003 - Am Physiological Soc
... The resulting skinned myocytes were resuspended in 8–10 ml of relaxing solution and kept on
ice throughout the days ... described previously (9). Skinned cardiac myocyte preparations were
attached between a capacitance-gauge transducer (model 403, Aurora Scientific) and a ...
Cited by 24 - Related articles - Get at CISTI - All 5 versions
Force-length relations in isolated intact cardiomyocytes subjected to dynamic changes in mechanical load
[HTML] from physiology.org




G Iribe, M Helmes… - American Journal of Physiology- …, 2007 - Am Physiological Soc
... Gentaro Iribe, 1 Michiel Helmes, 1 ,2 and Peter Kohl 1. ... CCD, charge-coupled device. K was
measured directly, using a force transducer system (406A; Aurora Scientific, Aurora, ON, Canada)
factory calibrated for compression measurement, and mounted under a microscope. ...
Cited by 30 - Related articles - Get at CISTI - All 7 versions
Mouse intact cardiac myocyte mechanics: cross-bridge and titin-based stress in unactivated cells
[HTML] from rupress.org




…, N Harrell, CS Chung, M Helmes… - The Journal of …, 2011 - jgp.rupress.org
... Results were compared with those of previous studies on skinned myocytes (Helmes et al., 1996,
2003; Preetha et al., 2005) and ... fibers protruding from pipette tip), and their stiffness was determined
by cross-calibrating with a force transducer (model 406A; Aurora Scientific). ...
Cited by 5 - Related articles - All 6 versions
Calcium sensitivity and the Frank-Starling mechanism of the heart are increased in titin N2B region-deficient mice
[HTML] from nih.gov




EJ Lee, J Peng, M Radke, M Gotthardt… - Journal of molecular and …, 2010 - Elsevier
... papillary muscles were dissected into small strips (cross-sectional area (CSA) 0.02 mm 2 ; length
1.2 mm) and small aluminum clips were glued to the ends of the muscle [33] in order to attach
the muscle at one end to a force transducer (model 406, Aurora Scientific) and at the ...
Cited by 5 - Related articles - All 6 versions
Analysing force–pCa curves
[HTML] from nih.gov





JS Walker, X Li… - Journal of muscle research and cell motility, 2010 - Springer
... Department of Medicine, University of Colorado Denver, Aurora, CO 80045, USA e-mail:
john.s.walker@ucdenver.edu ... contrast ability at magnifications up to 400 9 . Sarcomere length
was measured for each myocyte using a image based system (Aurora Scientific 901A HSVL ...
Cited by 4 - Related articles - All 7 versions
Mouse intact cardiac myocyte mechanics: cross-bridge and titin-based stress in unactivated cells



[HTML] from rupress.org
NMP King, M Methawasin, J Nedrud… - The Journal of …, 2011 - jgp.rupress.org
... Next, 10 ml of myocyte stopping buffer 2 was added (perfusion buffer plus 0.05 ml BCS/ml buffer
and 12.5 μM CaCl 2 ... mm of carbon fibers protruding from pipette tip), and their stiffness was
determined by cross-calibrating with a force transducer (model 406A; Aurora Scientific). ...
Cited by 5 - Related articles - All 6 versions
Inorganic phosphate speeds loaded shortening in rat skinned cardiac myocytes
[HTML] from physiology.org





AC Hinken… - American Journal of Physiology- …, 2004 - Am Physiological Soc
... were introduced at one end of the preparation with a direct current (DC) torque motor (model
308; Aurora Scientific) driven by ... window In a new window. Table 2. Effects of P i addition on
mechanical properties of skinned cardiac myocyte preparations. ... 2. Araujo A and Walker JW. ...
Cited by 16 - Related articles - Get at CISTI - All 5 versions
Protein Kinase A–Mediated Acceleration of the Stretch Activation Response in Murine Skinned Myocardium Is
Eliminated by Ablation of cMyBP-C
[HTML] from ahajournals.org





JE Stelzer, JR Patel… - Circulation research, 2006 - Am Heart Assoc
... The ends of the preparation were attached to the arms of a motor (model 312B, Aurora Scientific)
and force transducer (model 403, Aurora Scientific), as described earlier. ... Circ Res. 1998; 83:
471–480. Abstract/FREE Full Text. ? de Tombe PP, Stienen GJM. ...
Cited by 41 - Related articles - Get at CISTI - All 7 versions
Cycling cross-bridges increase myocardial stiffness at submaximal levels of Ca2+ activation
[HTML] from nih.gov





KS Campbell, JR Patel… - Biophysical journal, 2003 - Elsevier
... 913 ± 53 μm, width 130 ± 12 μm) were connected between a motor (Model 312B, time for
100-μm step 1 ms, Aurora Scientific, Ontario, Canada ... Many previous reports (Noble, 1977; Chiu
et al., 1982; de Tombe and ter Keurs, 1992; [Stuyvers et al., 1997] and [Stuyvers et al., 1998 ...
Cited by 26 - Related articles - Get at CISTI - All 11 versions
Effect of stimulation rate, sarcomere length and Ca2+ on force generation by mouse cardiac muscle
[HTML] from physoc.org




BD Stuyvers, AD McCulloch, J Guo… - The Journal of …, 2002 - Physiological Soc
... The length of the muscle (ML) was set using a servo-controlled motor (model 318 B, Aurora
Scientific Inc., Aurora, ON, Canada) hooked to ... carbon fibre rod, constituted the force transducer
so that the resolution of the force measurement system was 0.5 μN (see Stuyvers et al. ...
Cited by 45 - Related articles - Get at CISTI - All 10 versions
Effects of thin and thick filament proteins on calcium binding and exchange with cardiac troponin C
[HTML] from nih.gov





JP Davis, C Norman, T Kobayashi, RJ Solaro… - Biophysical journal, 2007 - Elsevier
... Aluminum T-clips were used to mount the trabecula between the arms of a high-speed
length controller (model 322C, Aurora Scientific, Ontario, Canada) and an isometric force
transducer (model 403A, Aurora Scientific) in relaxing solution. ...
Cited by 39 - Related articles - Get at CISTI - All 8 versions
Fabrication and Evaluation of Reconstructed Cardiac Tissue and Its Application to Bio-actuated Microdevices
H Horiguchi, K Imagawa, T Hoshino… - NanoBioscience, …, 2009 - ieeexplore.ieee.org
... D. Contractile Force Measurement of the Reconstructed Cardiac Tissue The contractile force of
the reconstructed cardiac tissue was measured using a force transducer. One end of the tissue
was fixed to a permeabilized fiber test apparatus (803B, Aurora Page 3. ...
Cited by 3 - Related articles - All 4 versions
The mechanoelectric feedback: a novel “calcium clamp” method, using tetanic contraction, for testing the role of
the intracellular free calcium
Y Yaniv, C Levy… - … of the New York Academy of …, 2006 - Wiley Online Library
... 308B, Aurora Scientific, Richmond Hill, Ontario, Canada) with a rise time of 250 μsec. ... from the
rat right ventricle (Spargue Dawley, 250–300 g). The dissection and the technique of mounting
the trabeculae in the experiment setup followed the procedures developed by ter Keurs. ...



Cited by 2 - Related articles - BL Direct - All 7 versions
Length dependence of force generation exhibit similarities between rat cardiac myocytes and skeletal muscle
fibres
[HTML] from physoc.org



LM Hanft… - The Journal of Physiology, 2010 - Wiley Online Library
... Length changes were introduced using a DC torque motor (model 308, Aurora Scientific, Inc.)
driven by voltage commands from a ... The kinetics of force redevelopment were obtained using
a procedure previously described for skinned cardiac myocyte preparations (Korte et al. ...


二、活體動物肌肉機械特性測試文獻


Plasmid-based gene transfer in mouse skeletal muscle by electroporation
JD Schertzer, GS Lynch - METHODS IN MOLECULAR BIOLOGY- …, 2008 - Springer
... 1. The measurement of TA muscle function in situ requires a suitable platform (which is usually
Plexiglas) to secure the anesthetized mouse and for appropriate positioning of the servomotor. ...
Suitable systems are commer- cially available (Aurora Scientific, Aurora, ON, Canada). ...
Cited by 7 - Related articles - BL Direct - All 4 versions



[HTML] < em> In Vivo</em> Canine Muscle Function Assay
[HTML] from jove.com




MK Childers, RW Grange… - Journal of Visualized …, 2011 - jove.com
... Stimulator, Grass, S88X, Stimulus isolation unit, Grass, SIU-C, Muscle lever system, Aurora
Scientific, 310C-LR, Footplate option. Signal interface, Aurora Scientific, Series 604A, Dynamic
Muscle Control & Analysis Software, Aurora Scientific, Aurora Scientific, ...
Cited by 1 - Related articles - Cached - All 4 versions
Monitoring Murine Skeletal Muscle Function for Muscle Gene Therapy
[HTML] from nih.gov




CH Hakim, D Li, D Duan, CH Hakim, D Li… - Methods in molecular …, 2011 - Springer
... 1. Physiological saline (0.9% NaCl). 2. In situ muscle function assay system (Aurora
Scientific). The system consists of a 305C-LR dual mode transducer, a 701B stimulator,
a 604A signal interface, and an 809A footplate apparatus (Fig. 1c). ...
Androgen replacement therapy improves function in male rat muscles independently of hypertrophy and
activation of the Akt/mTOR pathway
C Hourde, C Jagerschmidt… - Acta …, 2009 - Wiley Online Library
... The right limbs were fixed with clamps (806A; Aurora Scientific, Aurora, Canada). The distal
tendons of the right soleus muscles were attached to a dual-mode lever arm system that measures
muscle isometric force (300C; Aurora Scientific) using a silk ligature. ...
Glutamine preserves skeletal muscle force during an inflammatory insult
BM Meador… - Muscle & nerve, 2009 - Wiley Online Library
... Force was measured using a dual-mode lever system, which controlled both length and
force/speed (305C-LR; Aurora Scientific). ... The ankle of the mouse was fixed in the servomotor's
footplate, with the talus (rotational center of the ankle joint) aligned with the servomotor axis. ...
Cited by 8 - Related articles - All 4 versions
Sarcolipin overexpression in rat slow twitch muscle inhibits sarcoplasmic reticulum Ca2+ uptake and impairs
contractile function
[HTML] from jbc.org



AR Tupling, M Asahi… - Journal of Biological Chemistry, 2002 - ASBMB
... Three days after DNA injection, electrically evoked muscle force was assessed in situ from the
soleus muscle from each hindlimb across a range ... using a Grass S88 stimulator, and force data
were collected on-line using a 640A signal interface (Aurora Scientific Inc.) connected ...
Cited by 45 - Related articles - BL Direct - All 4 versions
Tibialis anterior muscles in mdx mice are highly susceptible to contraction-induced injury
[PDF] from 141.213.232.243
C Dellorusso, RW Crawford, JS Chamberlain… - Journal of muscle …, 2001 - Springer
... no. 85-23 (NIH), Revised 1985, Office of Science and Health reports, Bethesda, MD). In
situ preparation ... The tendon of the muscle was tied securely to the lever arm of a servomotor
(Model 305B-LR, Aurora Scientific, Richmond Hill, ON, Canada). ...


產品留言
標題
聯(lián)系人
聯(lián)系電話
內容
驗證碼
點擊換一張
注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發(fā)送信息!
2.如有必要,請您留下您的詳細聯(lián)系方式!
Copyright@ 2003-2025  世聯(lián)博研(北京)科技有限公司版權所有      電話:13466675923 傳真: 地址:北京市海淀區(qū)西三旗上奧世紀中心A座9層906 郵編:100096

泸溪县| 蒲江县| 开鲁县| 甘孜县| 江北区| 综艺| 绍兴县| 滦平县| 南澳县| 井陉县| 东山县| 息烽县| 临汾市| 绥棱县| 会理县| 离岛区| 克什克腾旗| 抚宁县| 乌审旗| 墨江| 靖宇县| 大余县| 光山县| 黄龙县| 荥阳市| 石门县| 舞阳县| 蓝山县| 宁乡县| 永城市| 吉木萨尔县| 广宁县| 汝城县| 阿克苏市| 和田县| 大英县| 齐河县| 金华市| 眉山市| 长垣县| 奉化市|