欧美亚洲日韩在线娱乐论坛,欧美亚洲国产一区二区三区,欧美日韩在线一区二区三区,欧美日韩一区二区三区人妻

世聯(lián)博研(北京)科技有限公司 主營(yíng):Flexcell細(xì)胞力學(xué)和regenhu細(xì)胞3D生物打印機(jī)銷售技術(shù)服務(wù): 美國(guó)Flexcell品牌FX-5000T細(xì)胞牽張應(yīng)力加載培養(yǎng)系統(tǒng),F(xiàn)X-5K細(xì)胞顯微牽張應(yīng)力加載培養(yǎng)系統(tǒng),Tissue Train三維細(xì)胞組織培養(yǎng)與測(cè)試系統(tǒng),F(xiàn)X-5000C三維細(xì)胞組織壓應(yīng)力加載培養(yǎng)系統(tǒng),STR-4000細(xì)胞流體剪切應(yīng)力加載培養(yǎng)系統(tǒng),德國(guó)cellastix品牌Optical Stretcher高通量單細(xì)胞牽引應(yīng)變與分析系統(tǒng) Regenhu品牌3D discovery細(xì)胞友好型3D生物打印機(jī),piuma細(xì)胞納米壓痕測(cè)試分析、aresis多點(diǎn)力學(xué)測(cè)試光鑷,MagneTherm細(xì)胞腫瘤電磁熱療測(cè)試分析系統(tǒng)
服務(wù)電話: 010-67529703
主營(yíng)產(chǎn)品: Flexcell細(xì)胞力學(xué)和regenhu細(xì)胞3D生物打印機(jī)銷售技術(shù)服務(wù): 美國(guó)Flexcell品牌FX-5000T細(xì)胞牽張應(yīng)力加載培養(yǎng)系統(tǒng),F(xiàn)X-5K細(xì)胞顯微牽張應(yīng)力加載培養(yǎng)系統(tǒng),Tissue Train三維細(xì)胞組織培養(yǎng)與測(cè)試系統(tǒng),F(xiàn)X-5000C三維細(xì)胞組織壓應(yīng)力加載培養(yǎng)系統(tǒng),STR-4000細(xì)胞流體剪切應(yīng)力加載培養(yǎng)系統(tǒng),德國(guó)cellastix品牌Optical Stretcher高通量單細(xì)胞牽引應(yīng)變與分析系統(tǒng) Regenhu品牌3D discovery細(xì)胞友好型3D生物打印機(jī),piuma細(xì)胞納米壓痕測(cè)試分析、aresis多點(diǎn)力學(xué)測(cè)試光鑷,MagneTherm細(xì)胞腫瘤電磁熱療測(cè)試分析系統(tǒng)
聯(lián)系我們

aurorascientific 300 C-IN,力學(xué)刺激器 - 壓頭300C-I Mechanical Stimulators – Indenter

  • 如果您對(duì)該產(chǎn)品感興趣的話,可以
  • 產(chǎn)品名稱:aurorascientific 300 C-IN,力學(xué)刺激器 - 壓頭300C-I Mechanical Stimulators – Indenter
  • 產(chǎn)品型號(hào):aurorascientific 300 C-IN,
  • 產(chǎn)品展商:aurorascientific
  • 產(chǎn)品文檔:無(wú)相關(guān)文檔
簡(jiǎn)單介紹

aurorascientific 300 C-IN,力學(xué)刺激器 - 壓頭300C-I Mechanical Stimulators – Indenter

產(chǎn)品描述

The 300C-I mechanical stimulator is an automated electronic von Frey device with the added capability to measure and control both force and length at a single application point. The 300C-I takes the variability and awkwardness out of applying force with a handheld von Frey filament or with other handheld mechanical stimulators. Our computer-controlled mechanical stimulator removes the unavoidable hand tremor associated with both von Frey filaments and other electronic von Frey systems. This removes the associated variation in force application.

Aurora Scientific’s mechanical stimulator increases throughput by eliminating the need for multiple tests to determine threshold. The force application and timing of the stimulus is consistent and precise, thereby removing the variability associated with handheld devices.

The mechanical stimulator is capable of applying constant force for pre-set periods of time with the added functionality of adjusting force at pre-determined rates. It can be applied in any combination of length or force and can follow an arbitrary force or distance application curve so force application is not limited to simple force ramps.

The delivery of constant and repeatable force ensures that consistency is maintained between experiments, subjects and studies, thus reducing avoidable error in your data and improving the quality of your findings.

 

  • quantify mechanosensitivity using computer-controlled stimuli
  • evaluate the supra threshold mechano sensitivity
  • measure the mechanical threshold without performing multiple tests
  • suitable for in-vitro, in-situ and ex-vivo preparations
  • force ranges: 50g, 100g
  • superior resolution (to 0.03g)
  • operates in any orientation
  • prevents production of off-axis forces
  • range of tips available (0.5, 0.8, 1, 1.5, 2, 3 mm diameter)
  • application area remains constant at all forces

    Customized 300C-I Facilitates Migraine Headache Research

    CHALLENGE

    In 2002 Dr. Dan Levy of Harvard University was studying the underlying mechanisms of migraine headaches and was looking for a method to reliably apply varying forces to sensory neurons innervating the dura mater of a rat.

    300C-I – Mechanical Stimulation of Rat Skin

    CHALLENGE

    In 1998 Dr. Woodbury approached us with a need to perform mechanical stimulation of rat skin stretched in a recording chamber. He needed a computer controlled mechanical stimulator that could produce controlled five second square waves of varying forces through a cylindrical indenter tip.

產(chǎn)品留言
標(biāo)題
聯(lián)系人
聯(lián)系電話
內(nèi)容
驗(yàn)證碼
點(diǎn)擊換一張
注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發(fā)送信息!
2.如有必要,請(qǐng)您留下您的詳細(xì)聯(lián)系方式!
Copyright@ 2003-2025  世聯(lián)博研(北京)科技有限公司版權(quán)所有      電話:13466675923 傳真: 地址:北京市海淀區(qū)西三旗上奧世紀(jì)中心A座9層906 郵編:100096

东兰县| 花垣县| 辉县市| 怀集县| 兰溪市| 外汇| 新平| 肇源县| 屏东县| 许昌县| 山东| 望江县| 麻栗坡县| 海口市| 兴隆县| 彭泽县| 大足县| 于田县| 凉城县| 七台河市| 邻水| 从江县| 鲜城| 巴林右旗| 沙田区| 静海县| 吉林省| 淳安县| 华安县| 平阴县| 岳西县| 保亭| 乌鲁木齐市| 巴塘县| 长顺县| 三原县| 宕昌县| 北宁市| 巍山| 仁怀市| 张掖市|