欧美亚洲日韩在线娱乐论坛,欧美亚洲国产一区二区三区,欧美日韩在线一区二区三区,欧美日韩一区二区三区人妻

世聯(lián)博研(北京)科技有限公司 主營:Flexcell細(xì)胞力學(xué)和regenhu細(xì)胞3D生物打印機銷售技術(shù)服務(wù): 美國Flexcell品牌FX-5000T細(xì)胞牽張應(yīng)力加載培養(yǎng)系統(tǒng),F(xiàn)X-5K細(xì)胞顯微牽張應(yīng)力加載培養(yǎng)系統(tǒng),Tissue Train三維細(xì)胞組織培養(yǎng)與測試系統(tǒng),F(xiàn)X-5000C三維細(xì)胞組織壓應(yīng)力加載培養(yǎng)系統(tǒng),STR-4000細(xì)胞流體剪切應(yīng)力加載培養(yǎng)系統(tǒng),德國cellastix品牌Optical Stretcher高通量單細(xì)胞牽引應(yīng)變與分析系統(tǒng) Regenhu品牌3D discovery細(xì)胞友好型3D生物打印機,piuma細(xì)胞納米壓痕測試分析、aresis多點力學(xué)測試光鑷,MagneTherm細(xì)胞腫瘤電磁熱療測試分析系統(tǒng)
服務(wù)電話: 010-67529703
主營產(chǎn)品: Flexcell細(xì)胞力學(xué)和regenhu細(xì)胞3D生物打印機銷售技術(shù)服務(wù): 美國Flexcell品牌FX-5000T細(xì)胞牽張應(yīng)力加載培養(yǎng)系統(tǒng),F(xiàn)X-5K細(xì)胞顯微牽張應(yīng)力加載培養(yǎng)系統(tǒng),Tissue Train三維細(xì)胞組織培養(yǎng)與測試系統(tǒng),F(xiàn)X-5000C三維細(xì)胞組織壓應(yīng)力加載培養(yǎng)系統(tǒng),STR-4000細(xì)胞流體剪切應(yīng)力加載培養(yǎng)系統(tǒng),德國cellastix品牌Optical Stretcher高通量單細(xì)胞牽引應(yīng)變與分析系統(tǒng) Regenhu品牌3D discovery細(xì)胞友好型3D生物打印機,piuma細(xì)胞納米壓痕測試分析、aresis多點力學(xué)測試光鑷,MagneTherm細(xì)胞腫瘤電磁熱療測試分析系統(tǒng)
聯(lián)系我們

biomomentum廠家Arthro-BST?壓關(guān)節(jié)軟骨電位電-機械性質(zhì)測量分析儀器系統(tǒng)

  • 如果您對該產(chǎn)品感興趣的話,可以
  • 產(chǎn)品名稱: biomomentum廠家Arthro-BST?壓關(guān)節(jié)軟骨電位電-機械性質(zhì)測量分析儀器系統(tǒng)
  • 產(chǎn)品型號:Arthroscopic Probe
  • 產(chǎn)品展商:biomomentum
  • 產(chǎn)品文檔:無相關(guān)文檔
簡單介紹

在軟骨評估中,現(xiàn)行的關(guān)節(jié)軟骨定量測量方法不能及時發(fā)現(xiàn)早期退行性改變。Arthro-BST?是一種新的醫(yī)療設(shè)備(圖1),可與關(guān)節(jié)鏡連用來定量測量關(guān)節(jié)軟骨??萍嘉墨I表明,流動電位既是軟骨的函數(shù),又是軟骨成分、結(jié)構(gòu)和厚度的函數(shù)。Arthro-BST?可測量輕壓關(guān)節(jié)軟骨時產(chǎn)生的流動電位,將其作為反映軟骨電-機械性質(zhì)的參數(shù)。

產(chǎn)品描述

 

系統(tǒng)簡介:

在軟骨評估中,現(xiàn)行的關(guān)節(jié)軟骨定量測量方法不能及時發(fā)現(xiàn)早期退行性改變。Arthro-BST?是一種新的醫(yī)療設(shè)備(圖1),可與關(guān)節(jié)鏡連用來定量測量關(guān)節(jié)軟骨??萍嘉墨I表明,流動電位既是軟骨的函數(shù),又是軟骨成分、結(jié)構(gòu)和厚度的函數(shù)。Arthro-BST?可測量輕壓關(guān)節(jié)軟骨時產(chǎn)生的流動電位,將其作為反映軟骨電-機械性質(zhì)的參數(shù)。

 

Arthro-BST?適用于測量軟骨中壓力導(dǎo)致的流動電位(圖2 A)。在測量時,通常用一個一次性無菌探針來輕壓關(guān)節(jié)軟骨表面,然后記錄產(chǎn)生的電信號。探針是一個覆蓋有37個微電*的球形表面(圖2 B)。儀器會記錄下來當(dāng)探針與軟骨接觸時總流動電位達到100 mV時使用的微電*數(shù),作為軟骨電機械活動的定量參數(shù)(QP)。高QP表示軟骨的電機械性質(zhì)較弱,低QP表示軟骨的電機械性質(zhì)較強(圖2 C)。

 

應(yīng)用范圍:

Arthro-BST?在軟骨修復(fù)研究中有著重要的應(yīng)用。

l  有助于理解軟骨**(如軟骨退行)的發(fā)病原因

l  開發(fā)新的**產(chǎn)品和軟骨修復(fù)技術(shù)

l  構(gòu)建穩(wěn)定的關(guān)節(jié)炎動物模型

 

應(yīng)用文獻:

Scientific Publications & Material Related to Arthro-BST?

2016

S. Sim, C. Becher, M. Garon, E. Quenneville, C. Hurschler and M.D. Buschmann. Comparison Between In Vitro and Simulated Arthroscopy Electromechanical Measurements of Human Articular Surfaces Using the Arthro-BST. International Cartilage Repair Society, Sorrento, Italy, Sept 2016. Poster #132

Sim S, Chevrier A, Garon M, Quenneville E, Lavigne P, Yaroshinsky A, Hoemann CD, Buschmann MD. Electromechanical probe and automated indentation maps are sensitive techniques in assessing early degenerated human articular cartilage. J Orthop Res. 2016 Jun 9. doi: 10.1002/jor.23330.Abstract

Jan C. Schagemann, Nicola Rudert, Michelle E. Taylor, Sotcheadt Sim, Eric Quenneville, Martin Garon, Mathias Klinger, Michael D. Buschmann, and Hagen Mittelstaedt (2016) Bilayer Implants: Electromechanical Assessment of Regenerated Articular Cartilage in a Sheep Model. Cartilage, 1947603515623992, first published on January 22, 2016. Abstract

2015

Mickevicius, T., Pockevicius, A., Kucinskas, A., Gudas, R., Maciulaitis, J., Noreikaite, A., and Usas, A. (2015). Impact of storage conditions on electromechanical, histological and histochemical properties of osteochondral allografts. BMC musculoskeletal disorders, 16(1), 314. Abstract, Article

Hadjab I., Sim S., E. Quenneville, M. Garon and M.D. Buschmann. (2015) Assessment of Human Articular Cartilage Issued from Asymptomatic and TKR Donors. Biomedical Engineering Society (BMES) Annual Meeting, Tampa, FL, USA. Presentation OP-Thurs-3-8. Thursday, October 8, 2015, 4:30 PM - 6:00 PM, Room 14.

Christoph Becher, Marcel Ricklefs, Elmar Willbold, Christof Hurschler, and Reza Abedian (2015) Electromechanical Assessment of Human Knee Articular Cartilage with Compression-Induced Streaming Potentials, Cartilage, 1947603515599191, first published on August 13, 2015. Abstract

S. Sim, A. Chevrier, M. Garon, E. Quenneville, and M.D. Buschmann. Correlation of Non-destructive Electromechanical Probe (Arthro-BST) Assessment with Histological Scores and Mechanical Properties in Human Tibial Plateau. Podium presentation 23.2.8 Osteoarthritis - Basic Science 2 and Biomechanics, Monday, May 11, 10:00 - 11:30, Chicago 9. Abstract / Presentation

S. Sim, I. Hadjab, M. Garon, E. Quenneville, M.B. Hurtig, M.D. Buschmann, and C.D. Hoemann. Evaluation of Entire Ovine Cartilage Repair Articular Surfaces: Mechanical and Electromechanical Assessment. Poster Presentation (P87). Abstract / Poster / ePoster

J.C. Schagemann, N. Rudert, S. Sim, E. Quenneville, M. Garon, M.E. Casper, M. Klinger, M.D. Buschmann, and H. Mittelstaedt. Correlation of Traditional and Novel Outcome Measures for the Assessment of Regenerated Osteochondral Tissue in a Sheep Model. Poster Presentation (P83). Abstract / Poster

S. Sim, A. Chevrier, M. Garon, E. Quenneville, and M.D. Buschmann. Correlation of Non-destructive Electromechanical Probe (Arthro-BST) Assessment with Histological Scores and Mechanical Properties in Human Tibial Plateau. OARSI 2015 World Congress on Osteoarthritis, April 30-3, 2015, Seattle, USA. Poster 368

S. Sim, A. Chevrier, M. Garon, E. Quenneville, and M.D. Buschmann. Correlation of Non-destructive Electromechanical Probe (Arthro-BST) Assessment with Histological Scores and Mechanical Properties in Human Tibial Plateau. 61st Annual Meeting of the ORS, March 28-30, 2015, Las Vegas, USA.Poster 1228

2014

S. Sim, A. Chevrier, M. Garon, E. Quenneville, A. Yaroshinsky, C.D. Hoemann and M.D. Buschmann. Non-destructive Electromechanical Assessment (Arthro-BST) of Human Articular Cartilage Correlates with Histological Scores and Biomechanical Properties. Osteoarthritis and Cartilage, 2014 Aug 25. pii: S1063-4584(14)01221-7. Abstract

A. Changoor, W. Brett, M.A. Hoba, M. Garon, E. Quenneville, K. Gordon, P. Savard, M.D. Buschmann, M.B. Hurtig and D.R. Trout. Electroarthrography, a non-invasive streaming potential-based method, measures cartilage quality in live horses. Osteoarthritis and Cartilage, Vol. 22, Supplement 1, 138, World Congress on Osteoarthritis, April 2014, Paris, France. Poster

S. Sim, A. Chevrier, M. Garon, E. Quenneville, and M.D. Buschmann. Correlation of Non-destructive Electromechanical Probe (Arthro-BST) Assessment with Histological Scores, Biochemical Composition and Mechanical Properties in Human Knee Joints. Transactions of the 60th Annual Meeting of the Orthopaedic Research Society, New Orleans, LA, USA, 0439. Poster

A. Changoor, M.A. Hoba, M. Garon, E. Quenneville, K. Gordon, P. Savard, M.D. Buschmann, M.B. Hurtig. Non-invasive Electroarthrography Correlates to Direct Measurements of Cartilage Streaming Potentials in Weight Bearing Regions of Equine Metacarpophalangeal (Fetlock) Joints. Transactions of the 60th Annual Meeting of the Orthopaedic Research Society, New Orleans, LA, USA, 1123. Poster

2013

S. Sim, A. Chevrier, E. Quenneville, M. Garon, and M.D. Buschmann. Correlation of Non-destructive Electromechanical Probe (Arthro-BST) Assessment with Histological Scores and Mechanical Properties in Human Knee Joints. Transactions International Cartilage Repair Society, P26, September 2013, Izmir, Turkey. Poster

Sim S., Picard G., Quenneville E., Garon M. and Buschmann M.D. (2013) The Spatial Pattern of Articular Cartilage Electromechanical Properties in the Stifle Joint is Similar in Three Different Species. Ecole Polytechnique of Montreal, Chemical Engineering Research Day, March 14th 2013. Presentation

Abedian R., Willbold E., Becher C. and Hurschler C. (2013) In vitro electro-mechanical characterization of human knee articular cartilage of different degeneration levels: A comparison with ICRS and Mankin scores. Journal of Biomechanics, accepted 5 February 2013, published online 11 March 2013.Abstract

Sim S., Picard G., Quenneville E., Garon M. and Buschmann M.D. (2013) The Spatial Pattern of Articular Cartilage Electromechanical Properties in the Stifle Joint is Similar in Three Different Species. Transactions of the 59th Annual Meeting of the Orthopaedic Research Society, San Antonio, TX, USA, 1975. Poster

Sim S., Picard G., Quenneville E., Garon M. and Buschmann M.D. (2013) Age-dependence of the Pattern of Cartilage Electromechanical Properties in the Ovine Stifle Joint Transactions of the 59th Annual Meeting of the Orthopaedic Research Society, San Antonio, TX, USA, 1976. Poster

Changoor A., Hoba M.A., Quenneville E., Garon M., Gordon K., Buschmann M.D., Savard P., Hurtig M.B. (2013) Electroarthrography Provides a Non-invasive Streaming Potential-Based Method for Detecting Cartilage Degeneration in an Equine Model Transactions of the 59th Annual Meeting of the Orthopaedic Research Society, San Antonio, TX, USA, 1974. Poster

2012

Sim S., Picard G., Quenneville E., Garon M. and Buschmann M.D. (2012) The Spatial Pattern of Articular Cartilage Electromechanical Properties in the Stifle Joint is Similar in Three Different Species. Groupe de recherche en sciences et technologies biomédicales (GRSTB) Symposium - Biomechanics and biomaterials, October 10, 2012, école Polytechnique de Montreal, Montreal, Quebec, Canada. Poster

2011

Presentation by Prof. Dr. Dani?l Saris, MD, PhD of the Arthro-BST at the ICRS 4th Surgical Skills Course, in Rostock (Germany), August 25-27, 2011.Video 

Report following the ICRS Laboratory Skills Course in Translational Science in Montreal (Quebec, Canada), from May 31 to June 3, 2011. Report

Changoor, A., Coutu, J. P., Garon, M., Quenneville, E., Hurtig, M. B., Buschmann, M. D. (2011) Streaming Potential-Based Arthroscopic Device is Sensitive to Cartilage Changes Immediately Post-Impact in an Equine Cartilage Injury Model. J. Biomech. Eng. 2011 Jun. 133(6):061005. Abstract

Changoor, Adele (2011) Electromechanical And Polarization Microscopy Evaluation Of Cartilage Repair And Degeneration, Ecole Polytechnique of Montreal, Ph.D. thesis. Thesis

2010

Changoor A, Fereydoonzad L, Yaroshinsky A, Buschmann MD. (2010) Effects of refrigeration and freezing on the electromechanical and biomechanical properties of articular cartilage. J Biomech Eng. 2010 Jun;132(6):064502. Abstract

2009

Changoor A., Quenneville E., Garon M., Hurtig M.B., Buschmann, M.D., (2009) Streaming Potential-Based Arthroscopic Device Can Detect Changes Immediately Following Localized Impact in an Equine Impact Model of Osteoarthritis. Osteoarthritis and Cartilage, Vol. 17, Supplement 1, S53, World Congress on Osteoarthritis, September 2009, Montreal, Quebec, Canada. Poster

2008

Hurtig M.B., Quenneville E., Garon M., Buschmann M.D. Legare A. (2008) Evaluation of a Medical Device for Assessment of Cartilage Degeneration After Impact Injury. Transactions of the 54th Annual Meeting of the Orthopaedic Research Society, San Francisco, CA, USA, 33:723. Poster

Garon M., Buschmann M.D., (2008) Non-Homogeneous Electromechanical Properties of articular Cartilage Predict an Electrical Potential of Positive Polarity outside Cartilage. Transactions of the 54th Annual Meeting of the Orthopaedic Research Society, San Francisco, CA, USA, 33:629. Poster

2007

Changoor A., Quenneville E., Garon M., Cloutier L., Hurtig M.B., Buschmann, M.D., (2007) Streaming Potential-Based Arthroscopic Device Discerns Topographical Differences In Cartilage Covered And Uncovered By Meniscus In Ovine Stifle Joints. Transactions of the 53th Annual Meeting of the Orthopaedic Research Society, San Diego, CA, USA, 32:631. Poster

Garon, Martin (2007) Conception et validation d'une sonde arthroscopique pour l'évaluation des propriétés électromécaniques fonctionnelles du cartilage articulaire (Conception and Validation of an Arthroscopique Probe for Evaluation of Functional Electromechanical Properties of Articular Cartilage), Ecole Polytechnique of Montreal, Ph.D. thesis. Thesis (in French with Abstract in English)

Garon M., Legare A., Quenneville E., Sims T.J., Hollander A.P., Shive M.S., Restrepo A., Buschmann M.D., (2007) Arthroscopic Device Measuring Streaming Potentials Reliably indicates Functional Properties of Cartilage. Osteoarthritis and Cartilage, Vol. 15, Supplement C, 254, World Congress on Osteoarthritis, December 2007, Ft. Lauderdale, Florida, USA. Poster

Garon M., Legare A., Quenneville E., Sims T.J., Hollander A.P., Hurtig M.B., Shive M.S., Buschmann M.D., (2007) Cartilage Streaming Potentials Measured with an Arthroscopic Medical Device Correlate with Site-specific Biochemical and Biomechanical Properties of Equine Articular Cartilage. Transactions International Cartilage Repair Society, 22.6, September 2007, Warsaw, Poland. Slides

Garon M., Legare A., Quenneville E., Sims T.J., Hollander A.P., Shive M.S., Restrepo A., Buschmann M.D., (2007) Streaming Potentials Measured with an Arthroscopic Medical Device are Reliable Indicators of Biochemical and Biomechanical Properties of Human Articular Cartilage. Transactions International Cartilage Repair Society, 5.3, September 2007, Warsaw, Poland. Slides

Garon M., Cloutier L., Legare A., Quenneville E., Shive M.S., Buschmann M.D., (2007) Reliability and Correlation to Human Articular Cartilage Mechanical Properties of a Streaming Potential based Arthroscopic Instrument. Transactions of the 53th Annual Meeting of the Orthopaedic Research Society, San Diego, CA, USA, 32:629. Poster

Larouche, Antoine (2007) Détermination de l'épaisseur du cartilage articulaire par mesures de la conductivité électrique (Determination of Articular Cartilage Thickness by Electrical Conductivity Measurements), Ecole Polytechnique of Montreal, Master in Applied Science (M.A.Sc.) Thesis.
Master Thesis (in French with Abstract in English)

Quenneville E, Garon M, Légaré A, Shive M, and Buschmann MD (2007a). Mapping Articular Cartilage Function using a Streaming Potential-based Arthroscopic Device. Transactions of the Segal North American Osteoarthritis Workshop (Chicago, USA). Poster

Quenneville E, Buschmann MD (2007b). A novel approach to predict diagnostic electric potential in cartilage. Transactions of the Orthopedic Research Society. 32 630. Poster | Abstract

2006

Changoor A., Quenneville E., Garon M., Cloutier L., Légaré A., Hurtig M.B., Buschmann M.D. (2006). Streaming potential-based arthroscopic device discerns topographical differences in cartilage covered and uncovered by meniscus in ovine stifle joints. Transactions of the Canadian Arthritis Network (Winnipeg, Canada). Poster

Li LP, Herzog W., (2006). Arthroscopic evaluation of cartilage degeneration using indentation testing--influence of indenter geometry. Clin. Biomech. May;21(4):420-6. Epub 2006 Feb 2. Abstract

Quenneville, Eric (2006) Les distributions de potentiel électrique dans le cartilage articulaire (Electrical Potential Distributions in Articular Cartilage), Ecole Polytechnique of Montreal, Ph.D. thesis. Thesis (in French with Abstract in English)

2005

Li LP, Herzog W., (2005). Electromechanical response of articular cartilage in indentation--considerations on the determination of cartilage properties during arthroscopy. Comput. Methods Biomech. and Biomed. Engin. Apr;8(2):83-91. Abstract

Quenneville E, Garon M, Légaré A, Garon M, and Buschmann MD. (2005a) Arthro-BST: A Diagnostic Instrument for the Functional Evaluation of Articular Cartilage. AITS Innovation Research Contest, Montréal, Mars 2005 Slides

Quenneville E., and Buschmann M.D. (2005b), A transport model of convection of electrolyte through a charged membrane predicts generation of net charge at membrane interfaces. Journal of Membrane Science, 265 (1-2), 60-73, 2005. Abstract

2004

Buschmann, M. D., Légaré, A., Garon, M. and Savard, P. (2004). Characterization of the Contact Distribution between Two Arbitrary Surfaces using Electrode Arrays. Patent 1199983 (Germany).

Quenneville E., Garon M., Legare A., Buschmann M.D., (2004a) Positive Electric Potentials Detected at the Cartilage/Bath Interface During Compression and their Importance in Clinical Cartilage Diagnostics. Transactions of the 50th Annual Meeting of the Orthopaedic Research Society, San Francisco, CA, USA, 29:528. Poster

Quenneville E, Garon M, and Buschmann MD. (2004b) Convection of electrolyte through a charged membrane produces net charge at membrane interfaces. Polyelectrolytes 2004, #S2-23, Amherst, USA (2004) Poster

Quenneville, E., Binette, J. S., Garon, M., Legare, A., Meunier, M. and Buschmann, M. D. (2004c). Fabrication and characterization of nonplanar microelectrode array circuits for use in arthroscopic diagnosis of cartilage diseases. IEEE Trans Biomed Eng. 51(12): 2164-73. Abstract

2003

Garon M., Legare A., Quenneville E., Hurtig M., Buschmann M.D., (2003) Streaming Potential Based Arthroscopic Instrument Distinguishes Site-Specific Properties of Equine Articular Cartilage. Transactions of the 49th Annual Meeting of the Orthopaedic Research Society, New Orleans, LA, USA, 28:255.Slides | Abstract

Quenneville E., Garon M., Legare A., Hurtig M., Buschmann M.D., (2003a) Load and Streaming Potential Responses of Articular Cartilage as a Function of Compression Speed during Indentation. Transactions of the 49th Annual Meeting of the Orthopaedic Research Society, New Orleans, LA, USA, 28:659. Poster

Quenneville E, Garon M, Légaré A, Garon M, Buschmann MD. (2003b) New Arthroscopic Device for Functional Mapping of Articular Cartilage. Trans. Joint IXth Canadian Connective Tissue Conference, #SS-1, Montreal, Canada, July 2003.

2002

Buschmann MD, Légaré A, Quenneville E, Garon M, and Hurtig MB. (2002) Mapping of the Functional Properties of Articular Cartilage via Streaming Potentials Measured with a New Arthroscopic Device. Trans. Osteoarthritis Consensus Conference, Toronto, April 2002

Garon M., Legare A., Guardo R., Savard P., Buschmann, M.D. (2002) Streaming Potentials Maps are Spatially Resolved Indicators of Amplitude, Frequency and Ionic Strength Dependant Responses of Articular Cartilage to Load. Journal of Biomechanics. 35, pp.207-216. Abstract

Legare A., Garon M., Guardo R., Savard P., Buschmann, M.D. (2002) Detection and Analysis of Cartilage Degeneration by Spatially Resolved Streaming Potentials. Journal of Orthopaedic Research. 20(4), pp. 208-215. Abstract

Quenneville E, Garon M, Légaré A, Garon M, Hurtig M, Buschmann MD. (2002a) Diagnostic Mapping of Articular Cartilage with a New Arthroscopic Device. Trans. International Cartilage Repair Society, Toronto, June 2002. Poster

Quenneville E, Garon M, Légaré A, Garon M, Hurtig M, and Buschmann MD. (2002b) Diagnostic Mapping of Bovine and Equine Articular Cartilage with a New Arthroscopic Device. Trans. Canadian Arthritis Network, Calgary, September 2002 Slides

2001

Garon M, Guardo R, and Buschmann MD. (2001) Estimation and sensitivity to cartilage degradation of electromechanical coupling coefficients derived using spatially resolved streaming potentials. Trans. Orthopaedic Research Society. San Francisco, USA, February 2001. Poster

Légaré A, Garon M, Binette F and Buschmann MD. (2001) Evaluation of Cartilage Quality using Streaming Potential Maps. International Cartilage Repair Society, 2001. Poster

Quenneville E, Légaré A, Garon M, Buschmann MD. (2001) Evaluation of an Arthroscopic Probe for the diagnosis of Cartilage Degradation. Canadian Arthitis Network Conference, Calgary, September 2001. Poster

2000

Buschmann, MD. (2000) Spatial Resolution of Mechanical Phenomena in Loaded Cartilage. The Whitaker Foundation Conference, San Diego, August 2000.

Légaré A, Garon M, Binette F and Buschmann MD. (2000a) Evaluation of Cartilage Quality using Streaming Potential Maps. International Cartilage Repair Society, Sweden, April 2000. Poster

Légaré A. (2000b) Functionnal Evaluation of Joint Diseases and Repair through Arthroscopic Non-Destructive Streaming Potential Measurements. Emerging Medical Technologies, California, 2000

1999

Légaré A, Garon M, Binette F, Guardo R, Savard P, and Buschmann MD. (1999) Characterization of Connective Tissue Using Streaming Potential Maps. Transactions 5th Canadian Connective Tissue Conference. Montreal, Canada, June 1999. Slides

1998

Buschmann, M. D., Guardo, R., Garon, M., Savard, P. and Le Guyader, P. (1998). A medical device for the diagnosis of cartilage degeneration via spatial mapping of compression-induced electrical potentials. Patent 5779651 (United States).

Légaré, A. (1998a). Détection de la dégénérescence du cartilage articulaire par la distribution spatiale des potentiels d'écoulement (Detection of Articulare Cartilage Degeneration by Streaming Potentials Spatial Distribution), Biomedical Engineering Institute, Montreal, Ecole Polytechnique of Montreal. Master in Applied Science (M.A.Sc.) Thesis.

Legare A., Garon M., Guardo R., LeGuyader P., Savard P., Buschmann M.D. (1998b) Detection of Cartilage Degeneration by Spatially Resolved Streaming Potentials. Transactions of the 44th Annual Meeting of the Orthopaedic Research Society, New Orleans, LA, USA, 23:659. Slides

1997

Garon M., Guardo R., Savard P., Buschmann M.D. (1997) Spatially Resolved Detection of Streaming Potentials in Articular Cartilage. Transactions of the 43th Annual Meeting of the Orthopaedic Research Society, San Francisco, CA, USA, 22:80. Slides

 

產(chǎn)品留言
標(biāo)題
聯(lián)系人
聯(lián)系電話
內(nèi)容
驗證碼
點擊換一張
注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發(fā)送信息!
2.如有必要,請您留下您的詳細(xì)聯(lián)系方式!
Copyright@ 2003-2025  世聯(lián)博研(北京)科技有限公司版權(quán)所有      電話:13466675923 傳真: 地址:北京市海淀區(qū)西三旗上奧世紀(jì)中心A座9層906 郵編:100096

天柱县| 江孜县| 昌黎县| 永清县| 邢台市| 荔波县| 峨眉山市| 青河县| 容城县| 宁武县| 舞钢市| 江达县| 苏尼特右旗| 中方县| 扶绥县| 昌图县| 曲水县| 壤塘县| 渝北区| 鄱阳县| 广宗县| 达孜县| 庆云县| 山阴县| 昌宁县| 桦甸市| 五指山市| 民勤县| 河南省| 中卫市| 辽源市| 瑞昌市| 尉犁县| 桐乡市| 灌阳县| 中宁县| 宜兰市| 克什克腾旗| 阿克陶县| 台北市| 南木林县|